Install a mechanical seal into a Viking Pump

Опубликовано: 07 Ноябрь 2024
на канале: Viking Pump®
700
11

Have questions? We'd love to chat! Send us a message here: https://www.vikingpump.com/yt

***Download the Technical Service Manual here: https://vp.salesmrc.com/item/12498

In this video we will guide you through the installation of a mechanical seal into one of Viking Pump’s internal gear pumps with the U-Plus™ bracket. To learn more or to see other repair videos, please visit our website at VikingPump.com.

This video applies to these pump models:
H4127C HL4127C K4127C KK4127C L4127C LL4127C LS4127C Q4127C QS4127C
H4227C HL4227C K4227C KK4227C L4227C LL4227C LS4227C Q4227C QS4227C

#VikingPump #modularity #serviceandrepair

▬ More Videos ▬▬▬▬▬▬▬▬▬▬▬▬
► All Viking Pump Videos:    / vikingpumpinc  
► Subscribe to Viking Pump Channel: https://bit.ly/2KJGmJT

▬ Social Media ▬▬▬▬▬▬▬▬▬▬▬▬▬▬▬
► Facebook:   / vikingpump  
► LinkedIn:   / viking-pump  
► Website: http://www.vikingpump.com

Welcome. In this Quick Tip video, we will show you how to install a component mechanical seal in the stuffing box in one of Viking Pump’s internal gear pumps with the U-Plus™ bracket.
Install the seal installation sleeve with the taper toward the end of the shaft.
Lubricate the shaft and install the rotary member of the mechanical seal.
Remember to remove the seal installation sleeve.
Before reaching the bracket bore, remove the four seal clips to engage the seal. Finish installing the seal until the set screws line up with the seal access hole in the bracket. Insert a hex head wrench into a set screw to keep the seal from sliding as you complete the rest of the installation.
Next, place the PTFE gasket around the stationary seal seat and slide onto the shaft.
Install the gasket into the seal holder and slide onto the shaft. Insert the T-bolts and install the locknuts, but do not fully tighten at this time.
Install the half-round rings. Install the bearing spacer collar with the cupped side over the half round rings.
Install the bearing housing and fully tighten until the shaft will not turn. This point is known as zero end clearance.
Install the lock washer by aligning the tab through the slot in the shaft.
Install the lock nut. Place a brass or hardwood bar into the port opening to keep the pump from turning. Torque the lock nut to the appropriate torque setting. This setting can be found in the technical service manual.
Remove the brass bar.
Bend a tang of the lock washer into a slot of the lock nut. If no tang aligns, continue to tighten the lock nut until one does. Failure to tighten the locknut or engage the lock washer tab could result in early bearing failure and cause damage to the rest of the pump.
You can now set the end clearance. The end clearance setting can be found in the technical service manual. Please refer to our video “Setting End Clearance” for details on this procedure.
You can now set the seal.
Confirm that the seal set screws are aligned with the seal access hole. Tighten each set screw until it just contacts the shaft. Then fully tighten each set screw.
Next, fully tighten the seal holder lock nuts.
Turn the shaft to ensure the pump turns freely.
Using appropriate thread sealant, install a plugs into the seal access holes.
To see the complete disassembly, seal installation, and final assembly visit our website at vikingpump.com.