Steel Beam Design Example | Book Steel Structures By Prof Dr Zahid Ahmad Siddiqui
Example 4.1: BEAMS WITH CONTINUOUS
LATERAL SUPPORT
Design a 7m long simply supported I-section beam subjected to service live load of 5 kN/m and imposed dead load of 6 kN/m, as shown in Figure
4.18. The compression flange is continuously supported.
Use (a) A36 steel and (b) steel with fy = 345 MPa and permissible live load deflection of span / 450.