Aspen plus V9.
In components Specifications
select Component ID:
click Find.
select Refrigerant (As R12)
Methods:
Base method : PENG-ROB
Now, Move to simulation
Step1: Select component and name them
1 Compressor ( from pressure changer )
2 After cooler ( From exchagers )
3 Expansion( from pressure changer )
4 Evaporator ( From exachager )
Step2: give Streams inbetween
Step3: Select streams S1
Presure :1 bar
Vapour fraction :0
Total flow basis :Mass
Total Flow rate :0
Component :1
Step4:select Blocks
For compressor -
Type : Isentropic
Discharge pressure : 3
Isentropic : 1
For after-cooler -
Vapor fraction :0
Presure drop :0
For Evaporator -
Vapor fraction :1
Presure drop :0
Expansion valve :
Check Adiabatic flash for specified outlet presuure
Outlet Pressure : 1 Bar
You're Done !!
Click on RUN!
and Check Results
Thank you!!
Song :
Heroic - Restless
LInk: • Heroic - Restless
Heroic - Lonely one
Link: • Heroic - Lonely one